null
Kaelus

KAELUS iQA Series Passive Intermodulation Test Set

Write a Review
Shipping:
Calculated at Checkout
On Sale
  • KAELUS iQA Series Passive Intermodulation Test Set
  • KAELUS iQA Series Passive Intermodulation Test Set
  • KAELUS iQA Series Passive Intermodulation Test Set
  • KAELUS iQA Series Passive Intermodulation Test Set
  • KAELUS iQA Series Passive Intermodulation Test Set
  • KAELUS iQA Series Passive Intermodulation Test Set
  • KAELUS iQA Series Passive Intermodulation Test Set
  • KAELUS iQA Series Passive Intermodulation Test Set
  • KAELUS iQA Series Passive Intermodulation Test Set
Now: $6,975.00
Was: $7,845.99

Description

Kaelus iQA-0850c Test Set.

The iQA series Passive Intermodulation (PIM) analyzer is a feature rich, high power PIM test solution. This field proven analyzer enables network operators to improve site performance by finding and eliminating sources of passive intermodulation at the cell site. The design includes an integrated panel PC with intuitive touch screen interface for performing tests and generating site reports. RTF module sold separately


- Rugged, reliable construction suitable for field use 

- Fully configurable frequencies, powers and IM products 

 - Integrated polycarbonate transit case 

- Simple to operate touch screen interface 

 - Range to Fault (RTF) enabled 

- Spectrum monitor, frequency sweep and time trace modes


iQA-0850C 

* 850MHz 
* tx range 869-894MHz 
* rx range 824-849MHz 
* Module - RTF-1000A


TECHNICAL SPECIFICATIONS |

SYSTEM

* Measurement method Reverse (reflected) PIM, 3rd, 5th, 7th, 9th and 11th order 
* Residual PIM < -115dBm/-158dBc max (<-125dBm/-168dBc typ) (x2 @ 20W) 
* User interface ports 3x USB, x1 LAN, 1x RF output (7-16 DIN female), 1x monitor port (N female) 
* Display 8.4in (213mm) touch screen display

TRANSMITTER

* Frequency increment 50 kHz 
* Frequency accuracy ± 5ppm (max), aging ± 1ppm (max) after first year 
* Power per tone (adjustable) 2x 2 to 20W (+33 to +43dBm) 
* Power accuracy (per tone) ± 0.5dB (max)

RECIEVER

* Receive band (50kHz steps) 
* Measurement noise floor < -128dBm 
* Measurement range -50dBm to -128dBm

ELECTRICAL

* Mains power 115-230V, 50/60Hz 
* AC Power consumption 650W

ENVIROMENTAL

* Operating temperature range -10°C to +40°C 
* Storage temperature range -20°C to +60°C 
* Ingress protection (IP) IP20 (with lid open) IP21 (with lid closed) 
* Relative humidity 5% to 95% RH non-condensing 
* Mechanical shock 40G shock rating


Dimensions 

* 19 x 18 x 12in (500 x 457 x 305mm) 
* Weight < 50lbs (22.7kg) 
* Cooling Forced air

View AllClose